Disposable & Reusable Biopsy Product

Biopsy is essential procedures used to examine the health of bone marrow and diagnose various conditions such as blood disorders, infections, and cancers. Several specialized needles and instruments are designed to perform these procedures with precision and ease. These single-use devices ensure a sterile, one-time use, preventing cross-contamination and minimizing infection risks during marrow collection.

Disposable Aspiration Biopsy Needle

The Clinical Advantages of AC 1 (compared to syringe):

  1. Complete product specification: We are the first in India to introduce the 25G ultra-fine needle to the domestic market. For thyroid nodules with a rich blood supply, the thinner the needle, the lower the ratio of blood components to nodule cells in the specimen, significantly reducing interference with light microscopic interpretation.
  2. Multi-cut tip: Provides a sharp puncture with minimal trauma.
  3. Echogenic design: Enhances visibility under ultrasound and facilitates accurate depth placement Apps.
  4. Ergonomic handle: Ensures a firm grip and good control.
  5. Coaxial needle structure: Prevents other cellular components on the puncture path from entering the needle lumen before the needle reaches the target nodule, thus avoiding contamination of the following sample and ensuring the accuracy of cytological diagnosis.

Cytological aspiration biopsy, amniotic fluid/cord blood aspiration biopsy, drug injection and sclerotherapy, cystic fluid aspiration therapy, etc.

GaugeLength 7cmLength 9cmLength 11cmLength 15cmLength 20cm
18GB-A301809B-A301811B-A301815B-A301820
20GB-A302009B-A302011B-A302015B-A302020
21GB-A302109B-A302111B-A302115B-A302120
22GB-A302209B-A302211B-A302215B-A302220
23GB-A302307B-A302309
25GB-A302509

Disposable Semi Automatic Biopsy Needle

Clinical Advantages of the AC 20 with Coaxial Needle for Puncture Biopsy:

  1.  Lightweight needle for easy control and accurate puncture site.
  2.  One puncture allows for multiple samplings, reducing the risk of complications.
  3. Provides access to biopsy needles, preventing tumor implantation. 4. Manages complications effectively.
Lung biopsy, thyroid biopsy, superficial lymph nodes biopsy, liver biopsy, kidney biopsy etc.
Sizes (in Gauge) Biopsy needle specifications Needle length Coaxial needle specifications Needle length
14G B-T041410 100mm B-T121305 50mm
B-T041416 160mm B-T121311 110mm
16G B-T041610 100mm B-T121505 50mm
B-T041616 160mm B-T121511 110mm
B-T041620 200mm B-T121515 150mm
18G B-T041810 100mm B-T121705 50mm
B-T041816 160mm B-T121711 110mm
B-T041820 200mm B-T121715 150mm
B-T041825 250mm
20G B-T042016 160mm B-T121911 110mm
Product Registration Certificate: name and model — Disposable biopsy needle (BN-OCR-2/GT20) | Disposable biopsy needle (BN-MAR-2/GTC)

Disposable Automatic Biopsy Needle

Operational Methods of AC400 Disposalble automatic Biopsy Needle

1. Cock the instrument Press the button. (order: left 1-right 2)
2. Puncture: Image-guided puncture to the edge of the lesion.
3. Unlock: Unlock the safety release button.
4. Fire: Choose the rear trigger or side trigger according to different needs and fire.
5. Get samples: Press the left button, and return the cannula.

Breast biopsy, prostate biopsy, kidney biopsy, lung biopsy, liver biopsy etc.
Gauge Specification Cannula length Coaxial needle specification Cannula length
14G B-T211410 10cm B-T121305 05cm
B-T211416 16cm B-T121311 11cm
B-T211420 20cm B-T121315 15cm
16G B-T211610 10cm B-T121505 05cm
B-T211616 16cm B-T121511 11cm
B-T211620 20cm B-T121515 15cm
18G B-T211810 10cm B-T121705 05cm
B-T211816 16cm B-T121711 11cm
B-T211820 20cm B-T121715 15cm
B-T211825 25cm B-T121720 20cm
20G B-T212010 10cm B-T121905 05cm
B-T212016 16cm B-T121911 11cm
B-T212020 20cm B-T121915 15cm

Disposable Full Core Biopsy Needle

Operational Methods of Disposable Full Core Biopsy Needle


1. Cock the instrument Pull up the white upper cover until you hear a “click” beep and press.
2. Choose biopsy length According to the lesion, choose biopsy length, press and move the two sides green stroke length adjuster together to the suitable gear.
3. Unlock Penetrate the needle to the lesion area, unlock the safety release button.
4. Fire: Fire the needle by press rear trigger or side trigger according to requirement.
5. Get samples: Pull up the white upper cover, the tissue sample gradually exposes. The needle is ready again to fire.

Lung biopsy, kidney biopsy, prostate biopsy, liver/pancreas biopsy, superficial lymph nodes biopsy and so on.
Sizes (in Gauge) Biopsy needle specifications Needle length
16G 16/10 13cm
16/15 18cm
16/20 23cm
18G 18/10 13cm
18/15 18cm
18/20 23cm

Reusable Gun - Reusable Automatic Biopsy Instrument

MC-MGN Disposable Biopsy Needle for Bard® Magnum® Automatic Biopsy Instrument

MegaCore 2
Specification: B-T271522
MC-MGN Needle Length 10cm Length 16cm Length 20cm Length 25cm
14G B-T101410 B-T101416 B-T101420
16G B-T101610 B-T101616 B-T101620
18G B-T101810 B-T101816 B-T101820 B-T101825
20G B-T102010 B-T102016 B-T102020

Only for professionals, refer to instructions for contraindications or precautions.

Anchor Disposable Pre-operative Localization Needle

Operational Methods of AC Anchor Pre-Operative Localization Needle

1. Puncture Under imaging guidance, the localization needle is punctured into the lesion area, reaching the central part of the tissue. If the lesion tissue is hard, it is necessary to penetrate the lesion tissue.

2. Localization needle release One hand fixes the localization wire, while the other hand withdraws the needle handle. When the needle handle is retracted to completely cover the tail-end marker, it indicates that the hook is in the release state

Pre-operative localization for breast biopsy, lung biopsy.
AC Anchor 1
Gauge Specification Cannula length
18G B-L701807 07cm
B-L701810 10cm
20G B-L702007 07cm
B-L702010 10cm
B-L702015 15cm
21G B-L702107 07cm
AC Anchor 2
Gauge Specification Cannula length
18G B-L721810 07cm
20G B-L722007 10cm
B-L722010 10cm

Only for professionals, refer to instructions for contraindications or precautions.

Disposable Bone Marrow Aspiration Needle

Operational Methods of AC 70 Disposable Bone Marrow Aspiration Needle

  1. Pre-operative preparation Choose a suitable puncture point and prepare the operation.
  2. Choose the right models Adults AC15/04, AC16/04, children AC18/03
  3.  Adjust the length of needle Hold the needle body with the left hand, and rotate the spiral counterclockwise with the right hand to adjust the length of the needle.
  4.  Puncture Use the left hand to fix the puncture point, the right hand to hold the needle, use the needle tip to penetrate into the bone vertically, can rotate left and right.
  5.  Post-operative dressing Re-Insert the needle stylet, and pull out the needle from the body. Press the puncture point and fix it with pressure.
  6.  Collect bone marrow fluid When the puncture resistance disappears and the puncture needle is fixed in the bone, pull out the needle stylet and attach a syringe to collect the bone marrow fluid.
Bone marrow biopsy (Cytology)
Specifications (Unit: G) Product Specifications Regular length of needle tube Minimum needle length Maximum needle length
15G AC 15/03 3cm 0.8cm 4.5cm
AC 15/04 4cm 2.3cm 6.0cm
16G AC 16/03 3cm 0.8cm 4.5cm
AC 16/04 4cm 2.3cm 6.0cm
18G AC 18/03 3cm 0.8cm 4.5cm

Registration certificate name and model: Biopsy needle (AC xx/yy)

Disposable Bone Marrow Biopsy Needle

Operational Methods of AC 2 Disposable Bone Marrow Aspiration Needle.

  1. Pre-operative preparation: Choose a suitable puncture point and prepare the operation.
  2. Choose the right models: BNMA/CB-1-2.4(13G)/70 for children, other models for adults
  3. Adjust the length of needle: Puncture into the bone cortex and continue down 0.5cm (Ergonomic handle, firm grip, good control).
  4. Change the safety cap: Rotate to remove the stylet, cap the safety cap to prevent contamination of the surgical field. Adjust the stopper 2cm from the body surface.
  5. Get the sample: Insert the S-Lock extraction cannula and rotate it together with cannula with 360 degree, Pull out them together, and get the sample.
  6. Continue to rotate and advance the needle Rotate and advance in one direction up to the stopper, and use the probe to measure the sample length.
Bone marrow biopsy (Hystology).
Gauge Length 7cm Length 10cm Length 15cm
7G B-B520710 B-B520715
8G B-B520810 B-B520815
9G B-B520910 B-B520915
11G B-B521107 B-B521110 B-B521115
13G B-B521307 B-B521310 B-B521315

Only for professionals, refer to instructions for contraindications or precautions.

Disposable Bone Marrow Transplantation Needle

Technical Advantages of AC 11

The unique design of 5 side holes for collecting bone marrow (6 holes in total)

Simultaneous multi-directional, multi-level high-quality marrow extraction. Effectively reduces the number of punctures and shortens the time for bone marrow collection. Simplifies the clinical operation process and reduces patient pain.

Bone marrow hematopoietic stem cell transplantation.
Gauge Specification Cannula Length
11G B-B511109 09cm
B-B511113 13cm
13G B-B511307 07cm
B-B511311 11cm
15G B-B511507 07cm
B-B511511 11cm

Disposable manual Bone marrow aspiration needle (Porous Type)

Operational Methods

  1. Preparation: The patient is positioned (lying on their side or stomach) and the area is cleaned and numbed with a local anesthetic.
  2. Needle Insertion: A small incision is made, and the needle is carefully inserted into the bone.
  3. Aspiration: A syringe is attached to the needle, and the bone marrow liquid is withdrawn.
  4. Sample Collection: The sample is then removed from the needle.
  5. Closure: Pressure is applied to the site, and a bandage is placed to promote healing and prevent infection.

Investigate lumps or masses.

GaugeModelLength (mm)
11G110550
110770
1110100
1115150
13G130550
130770
1310100
1315150

Disposable manual bone biopsy needle (Disconnector Type)

  1. Equipped with a sampler for easy sample removal.
  2. External cutter, easy to cut bone tissue.
  3. Standard syringe luer port, spiration/biopsy are both acceptable.
  4. Cutting-edge ve-sided cutting, ecient and labor-saving extraction of bone marrow.
  5. The tapered design of the needle tube prevents the sample from slipping.

GaugeModelLength (mm)
8G080550
080770
0810100
0815150
9G090550
090770
0910100
0915150
11G110550
110770
1110100
1115150
13G130550
130770
1310100
1315150

Disposable manual bone biopsy needle (built-in disconnector)

Gauge Model Length (mm)
8G 0805 50
0807 70
0810 100
0815 150
9G 0905 50
0907 70
0910 100
0915 150
11G 1105 50
1107 70
1110 100
1115 150
13G 1305 50
1307 70
1309 90
1310 100
1315 150
Scroll to Top