Disposable & Reusable Biopsy Product

Biopsy is essential procedures used to examine the health of bone marrow and diagnose various conditions such as blood disorders, infections, and cancers. Several specialized needles and instruments are designed to perform these procedures with precision and ease. These single-use devices ensure a sterile, one-time use, preventing cross-contamination and minimizing infection risks during marrow collection.

Disposable Aspiration Biopsy Needle

The Clinical Advantages of AC 1 (compared to syringe):

  1. Complete product specification: We are the first in India to introduce the 25G ultra-fine needle to the domestic market. For thyroid nodules with a rich blood supply, the thinner the needle, the lower the ratio of blood components to nodule cells in the specimen, significantly reducing interference with light microscopic interpretation.
  2. Multi-cut tip: Provides a sharp puncture with minimal trauma.
  3. Echogenic design: Enhances visibility under ultrasound and facilitates accurate depth placement Apps.
  4. Ergonomic handle: Ensures a firm grip and good control.
  5. Coaxial needle structure: Prevents other cellular components on the puncture path from entering the needle lumen before the needle reaches the target nodule, thus avoiding contamination of the following sample and ensuring the accuracy of cytological diagnosis.

Cytological aspiration biopsy, amniotic fluid/cord blood aspiration biopsy, drug injection and sclerotherapy, cystic fluid aspiration therapy, etc.

GaugeLength 7cmLength 9cmLength 11cmLength 15cmLength 20cm
18GB-A301809B-A301811B-A301815B-A301820
20GB-A302009B-A302011B-A302015B-A302020
21GB-A302109B-A302111B-A302115B-A302120
22GB-A302209B-A302211B-A302215B-A302220
23GB-A302307B-A302309
25GB-A302509

Disposable Semi Automatic Biopsy Needle

Clinical Advantages of the AC 20 with Coaxial Needle for Puncture Biopsy:

  1.  Lightweight needle for easy control and accurate puncture site.
  2.  One puncture allows for multiple samplings, reducing the risk of complications.
  3. Provides access to biopsy needles, preventing tumor implantation. 4. Manages complications effectively.
Lung biopsy, thyroid biopsy, superficial lymph nodes biopsy, liver biopsy, kidney biopsy etc.
Sizes (in Gauge)Biopsy needle specificationsNeedle lengthCoaxial needle specificationsNeedle length
14GB-T041410100mmB-T12130550mm
B-T041416160mmB-T121311110mm
16GB-T041610100mmB-T12150550mm
B-T041616160mmB-T121511110mm
B-T041620200mmB-T121515150mm
18GB-T041810100mmB-T12170550mm
B-T041816160mmB-T121711110mm
B-T041820200mmB-T121715150mm
B-T041825250mm
20GB-T042016160mmB-T121911110mm
Product Registration Certificate: name and model — Disposable biopsy needle (BN-OCR-2/GT20) | Disposable biopsy needle (BN-MAR-2/GTC)

Disposable Automatic Biopsy Needle

Operational Methods of AC400 Disposalble automatic Biopsy Needle

1. Cock the instrument Press the button. (order: left 1-right 2)
2. Puncture: Image-guided puncture to the edge of the lesion.
3. Unlock: Unlock the safety release button.
4. Fire: Choose the rear trigger or side trigger according to different needs and fire.
5. Get samples: Press the left button, and return the cannula.

Breast biopsy, prostate biopsy, kidney biopsy, lung biopsy, liver biopsy etc.
GaugeSpecificationCannula lengthCoaxial needle specificationCannula length
14GB-T21141010cmB-T12130505cm
B-T21141616cmB-T12131111cm
B-T21142020cmB-T12131515cm
16GB-T21161010cmB-T12150505cm
B-T21161616cmB-T12151111cm
B-T21162020cmB-T12151515cm
18GB-T21181010cmB-T12170505cm
B-T21181616cmB-T12171111cm
B-T21182020cmB-T12171515cm
B-T21182525cmB-T12172020cm
20GB-T21201010cmB-T12190505cm
B-T21201616cmB-T12191111cm
B-T21202020cmB-T12191515cm

Disposable Full Core Biopsy Needle

Operational Methods of Disposable Full Core Biopsy Needle


1. Cock the instrument Pull up the white upper cover until you hear a “click” beep and press.
2. Choose biopsy length According to the lesion, choose biopsy length, press and move the two sides green stroke length adjuster together to the suitable gear.
3. Unlock Penetrate the needle to the lesion area, unlock the safety release button.
4. Fire: Fire the needle by press rear trigger or side trigger according to requirement.
5. Get samples: Pull up the white upper cover, the tissue sample gradually exposes. The needle is ready again to fire.

Lung biopsy, kidney biopsy, prostate biopsy, liver/pancreas biopsy, superficial lymph nodes biopsy and so on.
Sizes (in Gauge)Biopsy needle specificationsNeedle length
16G16/1013cm
16/1518cm
16/2023cm
18G18/1013cm
18/1518cm
18/2023cm

Reusable Gun - Reusable Automatic Biopsy Instrument

MC-MGN Disposable Biopsy Needle for Bard® Magnum® Automatic Biopsy Instrument

MegaCore 2
Specification: B-T271522
MC-MGN NeedleLength 10cmLength 16cmLength 20cmLength 25cm
14GB-T101410B-T101416B-T101420
16GB-T101610B-T101616B-T101620
18GB-T101810B-T101816B-T101820B-T101825
20GB-T102010B-T102016B-T102020

Only for professionals, refer to instructions for contraindications or precautions.

Anchor Disposable Pre-operative Localization Needle

Operational Methods of AC Anchor Pre-Operative Localization Needle

1. Puncture Under imaging guidance, the localization needle is punctured into the lesion area, reaching the central part of the tissue. If the lesion tissue is hard, it is necessary to penetrate the lesion tissue.

2. Localization needle release One hand fixes the localization wire, while the other hand withdraws the needle handle. When the needle handle is retracted to completely cover the tail-end marker, it indicates that the hook is in the release state

Pre-operative localization for breast biopsy, lung biopsy.
AC Anchor 1
GaugeSpecificationCannula length
18GB-L70180707cm
B-L70181010cm
20GB-L70200707cm
B-L70201010cm
B-L70201515cm
21GB-L70210707cm
AC Anchor 2
GaugeSpecificationCannula length
18GB-L72181007cm
20GB-L72200710cm
B-L72201010cm

Only for professionals, refer to instructions for contraindications or precautions.

Disposable Bone Marrow Aspiration Needle

Operational Methods of AC 70 Disposable Bone Marrow Aspiration Needle

  1. Pre-operative preparation Choose a suitable puncture point and prepare the operation.
  2. Choose the right models Adults AC15/04, AC16/04, children AC18/03
  3.  Adjust the length of needle Hold the needle body with the left hand, and rotate the spiral counterclockwise with the right hand to adjust the length of the needle.
  4.  Puncture Use the left hand to fix the puncture point, the right hand to hold the needle, use the needle tip to penetrate into the bone vertically, can rotate left and right.
  5.  Post-operative dressing Re-Insert the needle stylet, and pull out the needle from the body. Press the puncture point and fix it with pressure.
  6.  Collect bone marrow fluid When the puncture resistance disappears and the puncture needle is fixed in the bone, pull out the needle stylet and attach a syringe to collect the bone marrow fluid.
Bone marrow biopsy (Cytology)
Specifications (Unit: G)Product SpecificationsRegular length of needle tubeMinimum needle lengthMaximum needle length
15GAC 15/033cm0.8cm4.5cm
AC 15/044cm2.3cm6.0cm
16GAC 16/033cm0.8cm4.5cm
AC 16/044cm2.3cm6.0cm
18GAC 18/033cm0.8cm4.5cm

Registration certificate name and model: Biopsy needle (AC xx/yy)

Disposable Bone Marrow Biopsy Needle

Operational Methods of AC 2 Disposable Bone Marrow Aspiration Needle.

  1. Pre-operative preparation: Choose a suitable puncture point and prepare the operation.
  2. Choose the right models: BNMA/CB-1-2.4(13G)/70 for children, other models for adults
  3. Adjust the length of needle: Puncture into the bone cortex and continue down 0.5cm (Ergonomic handle, firm grip, good control).
  4. Change the safety cap: Rotate to remove the stylet, cap the safety cap to prevent contamination of the surgical field. Adjust the stopper 2cm from the body surface.
  5. Get the sample: Insert the S-Lock extraction cannula and rotate it together with cannula with 360 degree, Pull out them together, and get the sample.
  6. Continue to rotate and advance the needle Rotate and advance in one direction up to the stopper, and use the probe to measure the sample length.
Bone marrow biopsy (Hystology).
GaugeLength 7cmLength 10cmLength 15cm
7GB-B520710B-B520715
8GB-B520810B-B520815
9GB-B520910B-B520915
11GB-B521107B-B521110B-B521115
13GB-B521307B-B521310B-B521315

Only for professionals, refer to instructions for contraindications or precautions.

Disposable Bone Marrow Transplantation Needle

Technical Advantages of AC 11

The unique design of 5 side holes for collecting bone marrow (6 holes in total)

Simultaneous multi-directional, multi-level high-quality marrow extraction. Effectively reduces the number of punctures and shortens the time for bone marrow collection. Simplifies the clinical operation process and reduces patient pain.

Bone marrow hematopoietic stem cell transplantation.
GaugeSpecificationCannula Length
11GB-B51110909cm
B-B51111313cm
13GB-B51130707cm
B-B51131111cm
15GB-B51150707cm
B-B51151111cm

Disposable manual Bone marrow aspiration needle (Porous Type)

Operational Methods

  1. Preparation: The patient is positioned (lying on their side or stomach) and the area is cleaned and numbed with a local anesthetic.
  2. Needle Insertion: A small incision is made, and the needle is carefully inserted into the bone.
  3. Aspiration: A syringe is attached to the needle, and the bone marrow liquid is withdrawn.
  4. Sample Collection: The sample is then removed from the needle.
  5. Closure: Pressure is applied to the site, and a bandage is placed to promote healing and prevent infection.

Investigate lumps or masses.

GaugeModelLength (mm)
11G110550
110770
1110100
1115150
13G130550
130770
1310100
1315150

Disposable manual bone biopsy needle (Disconnector Type)

  1. Equipped with a sampler for easy sample removal.
  2. External cutter, easy to cut bone tissue.
  3. Standard syringe luer port, spiration/biopsy are both acceptable.
  4. Cutting-edge ve-sided cutting, ecient and labor-saving extraction of bone marrow.
  5. The tapered design of the needle tube prevents the sample from slipping.

GaugeModelLength (mm)
8G080550
080770
0810100
0815150
9G090550
090770
0910100
0915150
11G110550
110770
1110100
1115150
13G130550
130770
1310100
1315150

Disposable manual bone biopsy needle (built-in disconnector)

GaugeModelLength (mm)
8G080550
080770
0810100
0815150
9G090550
090770
0910100
0915150
11G110550
110770
1110100
1115150
13G130550
130770
130990
1310100
1315150
Scroll to Top

Send An Enquiry

Call Now Button